PROBLEM
CAUSE PROCEDURE
5.Interior air circulation
a.Evaporator Fan not
running
b.Restriction in air ducts
c.Air control open too wide
6.Abnormal use
7.Bad door seal or door not
closing
8.High ambient temperature
9.Cabinet light(s)
10. Excessive frost on
evaporator unit:
a.Compressor won’t run
b.Compressor runs
continuously
5.
a.Check evaporator fan motor winding,
replace if defective.
b.Remove obstruction in ducts.
c.Adjust rear panel on air tower.
6.Instruct customer
7.a.Adjust door to obtain proper door seal.
b.Instruct customer to make sure door
closes completely.
8.Locate in area out of direct sunlight and
away from air vents and other source
of heat.
9.Check to make sure door switch is closed,
replace or adjust switch.
10. Check items under “Incomplete
Defrosting”
a.See “Compressor Won’t Run”
b.See “Compressor runs, but no
refrigeration or insufficient refrigeration.”
Call for a qualified service technician.
Freezer compartment too
warm (con’t.)
Refrigerator compartment too
warm
(Parts of this diagnosis and
service procedure must be
performed by a qualified
refrigeration system service
technician.)
1.Thermostat
a.Set too warm
b.Sensing tube not properly
located
c.Out of calibration or not
functioning
2.Air control closed
3.Abnormal use
4.Bad door seal or door not
closing
5.High ambient temperature
6.Cabinet light(s)
7.Excessive frost on
evaporator unit:
a.Compressor won’t run
b.Compressor runs
continuously
1.
a.Turn knob to higher setting.
b.See that sensing tube is properly
positioned and pressed into retainer
clips.
c.Check thermostat for cutin and cut-
out temperatures, recalibrate or
replace.
2.Adjust rear panel on air tower.
3.Instruct customer.
4.a.Adjust door to obtain proper door seal.
b.Instruct customer to make sure door
closes completely.
5.Locate in area out of direct sunlight and
away from air vents and other source
of heat.
6.Check to make sure door switch is closed,
replace or adjust switch.
7.Check items under “Incomplete
Defrosting”.
a.See “Compressor Won’t Run”.
b.See “Compressor runs, but no refrig-
eration or insufficient refrigeration.”
Call for a qualified service technician.