Roper TOP-MOUNT REFRIGERATOR Specifications Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 108
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
38
NEW DESIGN 14 cu. ft. Top-Mount
Air Circulation
The evaporator fan circulates air inside of the refrigerator and freezer section.
(Fig. 45)
Most of the air
circulates in the freezer compartment, where it travels to the front and passes through the series of
slots in the inner floor. The air then travels toward the back of the freezer between the inner floor and
the liner, where it passes under the evaporator cover, across the evaporator coils and back into the
freezer through a series of slots in the air tower.
Some of the air in the air tower travels down the chimney into the refrigerator compartment, and is
discharged through the front (narrow slot) and back (wide slot) of the diffuser.
(Fig. 45, INSET)
The
fan draws circulating air from the refrigerator through two return air ducts at the back of the separator.
From there the air travels up behind the evaporator cover and across the evaporator coils.
The fan again forces the air into the freezer and refrigerator compartments, to complete the cycle.
Fig. 45
RETURN
AIR DUCT
EVAPORATOR
COVER
EVAPORATOR FAN
AIR TOWER
INNER
FLOOR
EVAPORATOR
SEPARATOR
RETURN
AIR DUCT
INSET
AIR FLOW
TOWARDS
BACK
AIR FLOW
TOWARDS
FRONT
NARROW
SLOT
WIDE
SLOT
DIFFUSER
Page view 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 107 108

Comments to this Manuals

No comments