NEW DESIGN 14 cu. ft. Top-Mount
Servicing the Thermostat
1. Pull the knob off the thermostat control.
2. Unclip the sensor tube from the groove at the back of the control box.
3. Lift the thermostat out of the tabs securing it to the control box.
4. Disconnect the three wire connectors from the terminals of the thermostat.
NOTE: The inside of the thermostat control knob has a wide and a narrow slot
(Fig. 50, Inset).
Match these slots with the tabs next to the thermostat shaft and
press the knob over the tabs.
ORANGE
WIRE
RED
WIRE
GREEN
WIRE
TAB
TAB
TAB
TABS
THERMOSTAT
UNSNAP SENSOR TUBE
FROM BACK OF UNIT
KNOB
WIDE
SLOT
NARROW
SLOT
Servicing the Freezer Section
The Bi-Metal, Evaporator Fan and Defrost Heater can all be accessed in the Freezer Section after
the Evaporator Cover has been removed.
Removing the Evaporator Cover
1. Open the freezer door and remove the ice cube trays and shelf.
2. Remove the two (2) Phillips screws (or plastic “canoe” clips) from the front of the freezer’s
inner floor.
(Fig. 51)
3. Remove the automatic ice maker, if present.
4. Remove the two (2) Phillips screws from the rear of the freezer’s inner floor and remove the
floor.
(Fig. 51)